SUMMARY FILE FOR PROJECT: N19L2 COVER INFORMATION: Experiment: Network Monitoring Experiment Exp. Code: N19L2 Start Day 143 is Thu 23 May 2019 MJD 58626 Schedule Version: 5.00 Processed by SCHED version: 11.50 Development version 11.5. Started Apr. 2 PI: Benito Marcote Address: JIVE Oude Hoogeveensedijk 4 7991PD Dwingeloo The Netherlands Phone: +31 521 596 508 EMAIL: marcote@jive.eu Fax: Phone during observation: +31 521 596 508 Observing mode: Notes: 18cm NME and ftp fringe test for Session 2 2019 (512 Mbps, L+R, 2-bit sampling, 2 MHz filters) v5: with out-stations COVER LETTER: This is the schedule for the 18cm NME and ftp fringe-test on 23rd May 2019 involving antennas: Jb2, Wb, Ef, Mc, On85, T6, Ur, Tr, Hh, Sv, Zc, Bd, Ir, Sr, Ar. Arecibo may join after 13:50UT. The NME uses a standard setup with 512 Mbps. The schedule consists of long integrations on calibrators J0927+3902 and J0126+2559. The following ftp-fringe tests are scheduled throughout the experiment (UT times): 12:15:00 (scan 2, 2 sec, J0927+3902) 12:45:00 (scan 4, 2 sec, J0927+3902) 13:15:00 (scan 6, 2 sec, J0927+3902) 13:45:00 (scan 8, 2 sec, J0927+3902) 14:15:00 (scan 10, 2 sec, J0126+2559) -- Arecibo joins 14:45:00 (scan 12, 2 sec, J0126+2559) Good luck with the session! Benito Marcote Mattermost: coms.evlbi.org CORRELATION REQUESTS (Defaults in parentheses): Correlator (Required if recording): JIVE Correlator average time (2 sec): 1.000 sec. Alternate average time (for spacecraft). 0.000 sec. Output spectral channels per baseband (16): 16 Correlator FFT size (128): 128 Number of antennas to be correlated: 15 Polarization (ON): ON Correlator weighting function (UNIFORM): UNIFORM Distribution tape (DAT): FTP Distribution format (FITS): FITS Source positions from: STANDARD Shipping address for correlator output: Benito Marcote Correlator Notes: May be with you DERIVED INFORMATION FOR CORRELATION: All scans Elapsed time for project (hours): 3.00 Total time in scheduled scans (hours): 2.33 Total time in recording scans (hours): 2.33 Total baseline hours (recording scans): 375.67 Projected max correlator output rate (kB/s): 778.2 Projected correlator output data size (MB): 5539.4 NOTES: Above numbers assume the same correlator parameters are used for all data. The 'baseline hours' include the autocorrelations (for data size calculations). The correlator output data rate is for real-time processing. Above numbers assume the same correlator parameters are used for all data. The recordings for a scan are assumed to start at the scan START minus PRESTART. Some stations (VLA, VLBA/MARK5C) wait for good data so the estimates may be high. STATIONS USED IN SCHEDULE: Station Code Latitude Longitude Elevation X Y Z Axis Offset JODRELL2 Jb 53.23396 2.30390 144. 3822846.760 -153802.280 5086285.900 0.458 WSTRBORK Wb 52.91529 -6.59391 71. 3828750.697 442589.218 5064921.570 4.950 EFLSBERG Ef 50.52483 -6.88361 417. 4033947.235 486990.794 4900431.002 0.014 MEDICINA Mc 44.52050 -11.64694 67. 4461369.672 919597.135 4449559.400 1.828 ONSALA85 O8 57.39307 -11.91777 58. 3370965.879 711466.198 5349664.201 2.150 TIANMA65 T6 31.09210 -121.13601 49. -2826708.648 4679237.066 3274667.551 0.000 URUMQI Ur 43.47151 -87.17814 2033. 228310.181 4631922.902 4367064.211 0.000 TORUN Tr 53.09546 -18.56406 134. 3638558.510 1221969.720 5077036.760 0.000 HART Hh -25.88975 -27.68540 1416. 5085442.761 2668263.809 -2768696.729 6.694 SVETLOE Sv 60.53235 -29.78194 86. 2730173.647 1562442.798 5529969.156 -0.008 ZELENCHK Zc 43.78781 -41.56517 1175. 3451207.507 3060375.422 4391915.056 -0.011 BADARY Bd 51.77026 -102.23392 822. -838201.103 3865751.555 4987670.892 -0.005 IRBENE Ir 57.55338 -21.85481 59. 3183649.314 1276902.989 5359264.710 0.000 SARDINIA Sr 39.49307 -9.24515 672. 4865182.766 791922.689 4035137.174 0.000 ARECIBO Ar 18.34417 66.75270 451. 2390486.900 -5564731.440 1994720.450 0.000 TR_VDIF Tv 53.09546 -18.56406 134. 3638558.510 1221969.720 5077036.760 0.000 CAMBG32M Cm 52.16695 -0.03715 83. 3920356.150 2542.020 5014284.420 1.503 DARNHALL Da 53.15630 2.53565 112. 3829087.899 -169568.955 5081082.346 0.000 DEFFORD De 52.10056 2.14445 90. 3923442.566 -146914.330 5009755.125 1.901 PICKMERE Pi 53.28872 2.44537 100. 3817549.956 -163031.141 5089896.654 0.000 Plate tectonic motion adjustments for MJD 58626 Station Code Station motions (m/yr) Adjusted positions X Y Z MJD0 X Y Z JODRELL2 Jb -0.0117 0.0170 0.0093 50449 3822846.498 -153801.899 5086286.108 WSTRBORK Wb -0.0135 0.0170 0.0087 50449 3828750.394 442589.599 5064921.765 EFLSBERG Ef -0.0144 0.0167 0.0106 56658 4033947.158 486990.884 4900431.059 MEDICINA Mc -0.0183 0.0187 0.0115 56658 4461369.573 919597.236 4449559.462 ONSALA85 O8 -0.0144 0.0145 0.0105 56658 3370965.801 711466.276 5349664.257 TIANMA65 T6 -0.0158 -0.0438 -0.0314 56658 -2826708.733 4679236.830 3274667.382 URUMQI Ur -0.0323 -0.0014 0.0049 56658 228310.007 4631922.894 4367064.237 TORUN Tr -0.0160 0.0165 0.0075 50449 3638558.152 1221970.088 5077036.928 HART Hh -0.0010 0.0192 0.0162 56658 5085442.755 2668263.913 -2768696.642 SVETLOE Sv -0.0185 0.0133 0.0083 56658 2730173.547 1562442.869 5529969.200 ZELENCHK Zc -0.0225 0.0140 0.0077 56658 3451207.386 3060375.497 4391915.098 BADARY Bd -0.0277 0.0007 -0.0025 56658 -838201.252 3865751.559 4987670.879 IRBENE Ir -0.0169 0.0153 0.0064 57707 3183649.272 1276903.027 5359264.726 SARDINIA Sr -0.0147 0.0185 0.0185 56641 4865182.686 791922.790 4035137.275 ARECIBO Ar 0.0099 0.0045 0.0101 52275 2390487.072 -5564731.361 1994720.625 TR_VDIF Tv -0.0160 0.0165 0.0075 50449 3638558.152 1221970.088 5077036.928 CAMBG32M Cm -0.0120 0.0173 0.0094 50449 3920355.881 2542.407 5014284.630 DARNHALL Da -0.0116 0.0171 0.0093 50449 3829087.639 -169568.573 5081082.555 DEFFORD De -0.0115 0.0173 0.0095 50449 3923442.308 -146913.943 5009755.339 PICKMERE Pi -0.0117 0.0170 0.0093 50449 3817549.695 -163030.760 5089896.862 BASELINE LENGTHS (km) Jb Wb Ef Mc O8 T6 Ur Tr Hh Sv Zc Bd Ir Sr Ar Tv Cm Da De Pi Jb 0 597 700 1402 1011 8418 6028 1388 8442 2082 3309 6156 1591 1757 6394 1388 198 18 127 11 Wb 597 0 267 1003 602 8090 5568 802 8240 1636 2729 5788 1095 1502 6898 802 452 612 600 606 Ef 700 267 0 757 832 8203 5652 853 8042 1804 2687 5930 1248 1238 6911 853 510 711 653 711 Mc 1402 1003 757 0 1429 8284 5631 1078 7453 2140 2368 6087 1609 593 7236 1078 1205 1409 1319 1413 O8 1011 602 832 1429 0 7646 5120 638 8525 1080 2538 5272 596 1992 7184 638 958 1029 1076 1016 T6 8418 8090 8203 8284 7646 0 3245 7550 10157 6759 6579 2748 7214 8652 11567 7550 8392 8431 8477 8420 Ur 6028 5568 5652 5631 5120 3245 0 4875 8853 4127 3586 1452 4580 6030 10690 4875 5957 6044 6075 6033 Tr 1388 802 853 1078 638 7550 4875 0 8108 1071 1971 5200 538 1666 7558 0 1253 1405 1400 1397 Hh 8442 8240 8042 7453 8525 10157 8853 8108 0 8697 7355 9833 8463 7061 9886 8108 8309 8441 8353 8449 Sv 2082 1636 1804 2140 1080 6759 4127 1071 8697 0 2015 4282 562 2718 7963 1071 2029 2100 2149 2086 Zc 3309 2729 2687 2368 2538 6579 3586 1971 7355 2015 0 4405 2046 2697 9015 1971 3156 3324 3300 3318 Bd 6156 5788 5930 6087 5272 2748 1452 5200 9833 4282 4405 0 4797 6549 10408 5200 6129 6171 6227 6158 Ir 1591 1095 1248 1609 596 7214 4580 538 8463 562 2046 4797 0 2195 7665 538 1512 1608 1642 1596 Sr 1757 1502 1238 593 1992 8652 6030 1666 7061 2718 2697 6549 2195 0 7120 1666 1573 1758 1649 1767 Ar 6394 6898 6911 7236 7184 11567 10690 7558 9886 7963 9015 10408 7665 7120 0 7558 6516 6380 6387 6387 Tv 1388 802 853 1078 638 7550 4875 0 8108 1071 1971 5200 538 1666 7558 0 1253 1405 1400 1397 Cm 198 452 510 1205 958 8392 5957 1253 8309 2029 3156 6129 1512 1573 6516 1253 0 206 150 209 Da 18 612 711 1409 1029 8431 6044 1405 8441 2100 3324 6171 1608 1758 6380 1405 206 0 120 16 De 127 600 653 1319 1076 8477 6075 1400 8353 2149 3300 6227 1642 1649 6387 1400 150 120 0 134 Pi 11 606 711 1413 1016 8420 6033 1397 8449 2086 3318 6158 1596 1767 6387 1397 209 16 134 0 RECORDING SYSTEM AND CALIBRATION INFORMATION: List of scan-dependent controls seen for recording timing. MINPAUSE: 10. PRESTART: 0. DISKS - Stations potentially recording on disks. Station Drive type DAR NBBC Tsys JODRELL2 MARK5C DBBC 16 CONT WSTRBORK MARK5C DBBC 16 GAP EFLSBERG MARK5C DBBC 16 CONT MEDICINA MARK5C DBBC 16 CONT ONSALA85 MARK5C DBBC 16 CONT TIANMA65 MARK5C DBBC 16 CONT URUMQI MARK5B DBBC 16 GAP TORUN MARK5B DBBC 8 CONT HART MARK5C DBBC 16 GAP SVETLOE MARK5B R1002 14 GAP ZELENCHK MARK5B R1002 14 GAP BADARY MARK5B R1002 14 GAP IRBENE MARK5C DBBC 16 GAP SARDINIA MARK5C DBBC 16 GAP ARECIBO MARK5A VLBA4 8 CONT TR_VDIF MARK5C DBBC 8 CONT CAMBG32M MARK5C NONE 16 GAP DARNHALL MARK5C NONE 16 GAP DEFFORD MARK5C NONE 16 GAP PICKMERE MARK5C NONE 16 GAP EXPERIMENT SUMMARY: Number of input scans: 13 Number of scans scheduled: 13 Number of stations: 20 Number of sources input: 2 Number of setup files used: 1 STATION SCAN SUMMARIES: Station Control Scans Scan Record Record Gbytes Hours Hours Scans JODRELL2 VEX 13 2.33 2.33 13 541. WSTRBORK VEX 13 2.33 2.33 13 541. EFLSBERG VEX 13 2.33 2.33 13 541. MEDICINA VEX 13 2.33 2.33 13 541. ONSALA85 VEX 13 2.33 2.33 13 541. TIANMA65 VEX 8 1.37 1.37 8 317. URUMQI VEX 8 1.37 1.37 8 315. TORUN VEX 13 2.33 2.33 13 538. HART VEX 8 1.37 1.37 8 317. SVETLOE VEX 13 2.33 2.33 13 538. ZELENCHK VEX 8 1.37 1.37 8 315. BADARY VEX 8 1.37 1.37 8 315. IRBENE VEX 13 2.33 2.33 13 541. SARDINIA VEX 13 2.33 2.33 13 541. ARECIBO VEX 5 0.97 0.97 5 223. TR_VDIF VEX 13 2.33 2.33 13 541. CAMBG32M VEX 13 2.33 2.33 13 541. DARNHALL VEX 13 2.33 2.33 13 541. DEFFORD VEX 13 2.33 2.33 13 541. PICKMERE VEX 13 2.33 2.33 13 541. Notes on the station scan summaries: "Record Scans" are periods of recording with no gap. The Mark5A disk systems have a limit of 1024 such scans. There are often multiple projects on a disk pack. If using MARK5A, try to keep above about 6 GB per record scan by using MINPAUSE and PRESTART to prevent short gaps. However, also try to prevent record scans of more than an hour to minimize risk to data from playback problems. MARK5C will have one observe scan per record scan and there is no limit to the number. SETUP FILES: The following setup groups are the same as group 1 below. 2:ZELENCHK 3:BADARY ======== Setup file: sess219.L512 Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: kvzr_l passed by Alexey Melnikov, Mar2014 Setup group: 1 Station: SVETLOE Total bit rate: 512 Format: MARK5B Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: Speedup factor: 1.00 Disk used to record data. 1st LO= 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A B A B A B A B A B A B A B A B The following frequency sets based on these setups were used. Frequency Set: 10 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 374.49 374.49 374.49 374.49 390.49 390.49 390.49 390.49 406.49 406.49 406.49 406.49 422.49 422.49 422.49 422.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 10 11 12 Track assignments are: track1= 18, 26, 2, 10, 20, 28, 4, 12, 22, 30, 6, 14, 24, 32, 8, 16 barrel=roll_off ======== Setup file: sess219.L512 Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: arlb5c RX=LBW, with lfbf=5, upper 300 MHz CS 15-May-06 Setup group: 4 Station: ARECIBO Total bit rate: 512 Format: MKIV1:2 Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: Speedup factor: 1.00 Disk used to record data. 1st LO= 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 2 1 2 3 4 3 4 5 6 5 6 7 8 7 8 BBC SB= U U L L U U L L U U L L U U L L IF = A C A C A C A C A C A C A C A C The following frequency sets based on these setups were used. Frequency Set: 20 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 765.51 765.51 765.51 765.51 749.51 749.51 749.51 749.51 733.51 733.51 733.51 733.51 717.51 717.51 717.51 717.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 20 Track assignments are: track1= 2, 10, 18, 26, 3, 11, 19, 27, 66, 74, 82, 90, 67, 75, 83, 91 barrel=roll_off ======== Setup file: sess219.L512 Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: ef18cm 18cm Prime focus receiver, standard LO ****** Only 64.00 of 128.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. Setup group: 5 Station: EFLSBERG Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 The following frequency sets based on these setups were used. Frequency Set: 3 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 124.49 124.49 124.49 124.49 140.49 140.49 140.49 140.49 156.49 156.49 156.49 156.49 172.49 172.49 172.49 172.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 3 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 6 Station: WSTRBORK Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 The following frequency sets based on these setups were used. Frequency Set: 2 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 387.49 387.49 387.49 387.49 403.49 403.49 403.49 403.49 419.49 419.49 419.49 419.49 435.49 435.49 435.49 435.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 2 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 7 Station: JODRELL2 Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 The following frequency sets based on these setups were used. Frequency Set: 1 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 637.51 637.51 637.51 637.51 621.51 621.51 621.51 621.51 605.51 605.51 605.51 605.51 589.51 589.51 589.51 589.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 1 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 8 Station: ONSALA85 Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 The following frequency sets based on these setups were used. Frequency Set: 5 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 414.49 414.49 414.49 414.49 430.49 430.49 430.49 430.49 446.49 446.49 446.49 446.49 462.49 462.49 462.49 462.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 5 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: hh18cm Values confirmed by E-mail Jonathan Quick 20140219 (CR) ****** Only 64.00 of 128.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. Setup group: 9 Station: HART Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 The following frequency sets based on these setups were used. Frequency Set: 9 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 124.49 124.49 124.49 124.49 140.49 140.49 140.49 140.49 156.49 156.49 156.49 156.49 172.49 172.49 172.49 172.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 9 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 10 Station: MEDICINA Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 1295.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 The following frequency sets based on these setups were used. Frequency Set: 4 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 339.49 339.49 339.49 339.49 355.49 355.49 355.49 355.49 371.49 371.49 371.49 371.49 387.49 387.49 387.49 387.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 4 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 11 Station: TORUN Total bit rate: 512 Format: MARK5B Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 The following frequency sets based on these setups were used. Frequency Set: 8 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 665.51 665.51 665.51 665.51 649.51 649.51 649.51 649.51 633.51 633.51 633.51 633.51 617.51 617.51 617.51 617.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 8 Track assignments are: track1= 2, 10, 18, 26, 4, 12, 20, 28, 6, 14, 22, 30, 8, 16, 24, 32 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 12 Station: TR_VDIF Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 2300.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 The following frequency sets based on these setups were used. Frequency Set: 15 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 665.51 665.51 665.51 665.51 649.51 649.51 649.51 649.51 633.51 633.51 633.51 633.51 617.51 617.51 617.51 617.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 15 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 13 Station: IRBENE Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 The following frequency sets based on these setups were used. Frequency Set: 13 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 284.49 284.49 284.49 284.49 300.49 300.49 300.49 300.49 316.49 316.49 316.49 316.49 332.49 332.49 332.49 332.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 13 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 14 Station: SARDINIA Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 2324.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 The following frequency sets based on these setups were used. Frequency Set: 14 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 689.51 689.51 689.51 689.51 673.51 673.51 673.51 673.51 657.51 657.51 657.51 657.51 641.51 641.51 641.51 641.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 14 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 15 Station: URUMQI Total bit rate: 512 Format: MARK5B Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 The following frequency sets based on these setups were used. Frequency Set: 7 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 334.49 334.49 334.49 334.49 350.49 350.49 350.49 350.49 366.49 366.49 366.49 366.49 382.49 382.49 382.49 382.49 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 7 Track assignments are: track1= 18, 26, 2, 10, 20, 28, 4, 12, 22, 30, 6, 14, 24, 32, 8, 16 barrel=roll_off ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 16 Station: TIANMA65 Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 2270.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 The following frequency sets based on these setups were used. Frequency Set: 6 Setup file default. Used with PCAL = off LO sum= 1634.49 1634.49 1634.49 1634.49 1650.49 1650.49 1650.49 1650.49 1666.49 1666.49 1666.49 1666.49 1682.49 1682.49 1682.49 1682.49 BBC fr= 635.51 635.51 635.51 635.51 619.51 619.51 619.51 619.51 603.51 603.51 603.51 603.51 587.51 587.51 587.51 587.51 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 6 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off The following setup groups are the same as group 17 below. 18:DARNHALL 19:PICKMERE 20:DEFFORD ======== Setup file: sess219.L512 --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 17 Station: CAMBG32M Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate:128.000 Number of channels: 2 DBE type: Speedup factor: 1.00 Disk used to record data. 1st LO= 2272.00 2272.00 Net SB= U U IF SB = L L Pol. = RCP LCP BBC = 1 9 BBC SB= L L IF = A1 B1 The following frequency sets based on these setups were used. Frequency Set: 16 Setup file default. Used with PCAL = off LO sum= 1626.49 1626.49 BBC fr= 645.51 645.51 Bandwd= 64.00 64.00 Matching frequency sets: 16 17 18 19 Track assignments are: track1= 1, 2 barrel=roll_off SCAN SUMMARY for experiment N19L2 Network Monitoring Experiment Flags: D=>Down, H=>Below Horizon, R=>Rises, S=>Sets, W=>Slew too long, t=>Tape Chg. Top item is: Start elevation. Bottom item is: Seconds antenna is on source before scan start. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 143 is Thu 23 May 2019 MJD 58626 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef Mc O8 T6 Ur Tr Hh Sv Zc Bd Ir Sr Ar Tv Cm Da De Pi 1 143 12:00:00 J0927+3902 - 34 39 38 39 43 57 84 46 8 52 60 71 48 36 ---D 46 35 34 33 34 143 12:04:00 sess219.L512 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---D 0 0 0 0 0 2 143 12:07:00 J0927+3902 - 35 40 39 41 44 55 83 47 9 53 61 70 49 37 ---D 47 36 35 34 35 143 12:17:00 - - 175 169 162 177 174 178 177 173 159 173 174 173 177 177 ---D 173 176 175 175 175 3 143 12:20:00 J0927+3902 - 37 42 41 43 45 53 81 49 11 54 64 68 51 39 ---D 49 38 36 36 37 143 12:32:00 - - 175 169 162 177 174 178 177 173 159 173 174 173 177 177 ---D 173 176 175 175 175 4 143 12:35:00 J0927+3902 - 39 44 44 45 47 50 78 51 13 56 66 66 53 42 ---D 51 40 39 39 39 143 12:47:00 - - 175 169 162 177 174 178 178 173 159 173 174 173 177 177 ---D 173 176 175 175 175 5 143 12:50:00 J0927+3902 - 41 46 46 48 49 47 75 53 15 58 69 64 55 45 ---D 53 42 41 41 41 143 13:02:00 - - 175 169 161 177 174 178 178 173 159 173 174 173 177 177 ---D 173 176 175 175 175 6 143 13:05:00 J0927+3902 - 43 48 48 51 51 44 73 56 16 59 72 61 57 48 ---D 56 44 43 43 43 143 13:17:00 - - 175 169 161 177 174 178 178 173 159 173 173 173 177 177 ---D 173 176 175 175 175 7 143 13:24:00 J0927+3902 - 46 51 51 54 54 40 69 58 18 61 75 58 59 51 ---D 58 47 46 46 46 143 13:32:00 - - 414 409 401 417 413 418 418 413 398 413 413 413 417 416 ---D 413 416 414 414 414 8 143 13:35:00 J0927+3902 - 48 53 53 56 55 38 67 60 19 62 77 57 60 53 ---D 60 49 47 48 48 143 13:47:00 - - 175 169 161 177 174 178 178 173 159 173 173 174 177 177 ---D 173 176 175 175 175 9 143 13:50:00 J0126+2559 - 36 31 30 26 28 ---D ---D 23 ---D 20 ---D ---D 23 27 82 23 35 36 36 36 143 14:02:00 - - -385 -239 -305 -41 -245 ---D ---D -191 ---D 0 ---D ---D 94 -6 0 -191 -121 -386 -392 -385 10 143 14:05:00 J0126+2559 - 34 28 28 24 26 ---D ---D 21 ---D 18 ---D ---D 21 24 82 21 32 34 34 34 143 14:17:00 - - 175 169 161 177 174 ---D ---D 173 ---D 174 ---D ---D 177 177 169 173 176 175 175 175 11 143 14:20:00 J0126+2559 - 31 26 25 21 24 ---D ---D 19 ---D 16 ---D ---D 19 21 80 19 30 32 31 32 143 14:32:00 - - 175 169 161 177 174 ---D ---D 173 ---D 174 ---D ---D 177 177 170 173 176 175 175 175 12 143 14:35:00 J0126+2559 - 29 24 23 18 22 ---D ---D 17 ---D 14 ---D ---D 17 18 77 17 28 29 29 29 143 14:47:00 - - 175 169 161 177 174 ---D ---D 173 ---D 174 ---D ---D 177 177 170 173 176 175 175 175 13 143 14:50:00 J0126+2559 - 27 22 21 16 20 ---D ---D 15 ---D 13 ---D ---D 15 16 74 15 25 27 27 27 143 15:00:00 - - 175 169S 161 177 174 ---D ---D 173 ---D 174 ---D ---D 177 177 170 173 176 175 175 175 SCAN SUMMARY for experiment N19L2 Network Monitoring Experiment Flags: D=>Down, H=>Below Horizon, R=>Rises, S=>Sets, W=>Slew too long, t=>Tape Chg. Top item is: Start azimuth. Bottom item is: End azimuth. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 143 is Thu 23 May 2019 MJD 58626 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef Mc O8 T6 Ur Tr Hh Sv Zc Bd Ir Sr Ar Tv Cm Da De Pi 1 143 12:00:00 J0927+3902 - 68 74 72 430 82 -65 227 82 39 460 445 597 -270 66 ---D 82 429 68 68 68 143 12:04:00 sess219.L512 - 69 75 73 431 82 -65 231 83 39 461 446 599 -269 66 ---D 83 430 69 68 69 2 143 12:07:00 J0927+3902 - 70 75 73 431 83 -65 235 84 38 462 446 600 -269 67 ---D 84 430 69 69 69 143 12:17:00 - - 71 77 75 433 85 -65 243 86 37 465 448 604 -267 68 ---D 86 432 71 70 71 3 143 12:20:00 J0927+3902 - 72 77 76 433 86 -65 245 86 36 466 449 605 -266 68 ---D 86 432 71 71 72 143 12:32:00 - - 74 79 77 435 88 -65 251 88 35 469 451 609 -263 69 ---D 88 434 73 73 74 4 143 12:35:00 J0927+3902 - 74 80 78 435 89 -65 253 89 34 470 451 610 -263 69 ---D 89 435 74 73 74 143 12:47:00 - - 76 82 80 437 91 -65 257 91 32 473 453 614 -260 70 ---D 91 437 76 75 76 5 143 12:50:00 J0927+3902 - 77 83 80 437 92 -65 258 92 32 474 454 614 -259 71 ---D 92 437 76 76 77 143 13:02:00 - - 79 85 82 438 94 -64 262 95 30 478 457 618 -256 72 ---D 95 439 79 78 79 6 143 13:05:00 J0927+3902 - 79 85 83 439 95 -64 262 95 29 479 457 618 -255 72 ---D 95 440 79 78 79 143 13:17:00 - - 81 88 85 441 98 -64 265 98 27 483 461 621 -252 73 ---D 98 442 81 80 81 7 143 13:24:00 J0927+3902 - 83 89 86 441 100 -63 267 100 26 485 463 623 -250 74 ---D 100 443 82 82 83 143 13:32:00 - - 84 91 88 443 101 -63 268 102 25 488 466 625 -247 75 ---D 102 445 84 83 84 8 143 13:35:00 J0927+3902 - 85 91 88 443 102 -63 269 102 24 489 467 625 -247 75 ---D 102 445 84 84 85 143 13:47:00 - - 87 94 91 445 105 -62 271 106 22 493 472 628 -243 76 ---D 106 447 87 86 87 9 143 13:50:00 J0126+2559 - 266 274 275 282 275 ---D ---D 283 ---D 649 ---D ---D -77 -77 362 283 629 266 267 266 143 14:02:00 - - 269 276 278 284 278 ---D ---D 285 ---D 651 ---D ---D -74 -76 343 285 631 269 270 269 10 143 14:05:00 J0126+2559 - 269 277 278 284 279 ---D ---D 285 ---D 652 ---D ---D -74 -75 338 285 632 269 270 269 143 14:17:00 - - 272 279 280 286 281 ---D ---D 288 ---D 654 ---D ---D -71 -73 323 288 634 272 273 272 11 143 14:20:00 J0126+2559 - 272 279 281 287 282 ---D ---D 288 ---D 655 ---D ---D -71 -73 320 288 635 272 273 272 143 14:32:00 - - 275 282 283 288 284 ---D ---D 290 ---D 657 ---D ---D -68 -71 311 290 637 275 276 275 12 143 14:35:00 J0126+2559 - 275 282 283 289 285 ---D ---D 291 ---D 658 ---D ---D -68 -71 309 291 638 275 276 275 143 14:47:00 - - 278 284 286 291 287 ---D ---D 293 ---D 660 ---D ---D -65 -69 303 293 640 278 278 278 13 143 14:50:00 J0126+2559 - 278 285 286 291 287 ---D ---D 294 ---D 661 ---D ---D -65 -69 302 294 641 278 279 278 143 15:00:00 - - 280 287D 288 293 289 ---D ---D 296 ---D 663 ---D ---D -63 -67 299 296 642 280 281 280 SCAN SUMMARY for experiment N19L2 Network Monitoring Experiment Top item is: Slew time in seconds from previous source. Bottom item is: Nothing requested with SUMITEM. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 143 is Thu 23 May 2019 MJD 58626 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef Mc O8 T6 Ur Tr Hh Sv Zc Bd Ir Sr Ar Tv Cm Da De Pi 1 143 12:00:00 J0927+3902 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --- 0 0 0 0 0 143 12:04:00 sess219.L512 - --- 2 143 12:07:00 J0927+3902 - 5 11 18 3 6 2 3 7 21 7 6 7 3 3 --- 7 4 5 5 5 143 12:17:00 - - --- 3 143 12:20:00 J0927+3902 - 5 11 18 3 6 2 3 7 21 7 6 7 3 3 --- 7 4 5 5 5 143 12:32:00 - - --- 4 143 12:35:00 J0927+3902 - 5 11 18 3 6 2 2 7 21 7 6 7 3 3 --- 7 4 5 5 5 143 12:47:00 - - --- 5 143 12:50:00 J0927+3902 - 5 11 19 3 6 2 2 7 21 7 6 7 3 3 --- 7 4 5 5 5 143 13:02:00 - - --- 6 143 13:05:00 J0927+3902 - 5 11 19 3 6 2 2 7 21 7 7 7 3 3 --- 7 4 5 5 5 143 13:17:00 - - --- 7 143 13:24:00 J0927+3902 - 6 11 19 3 7 2 2 7 22 7 7 7 3 4 --- 7 4 6 6 6 143 13:32:00 - - --- 8 143 13:35:00 J0927+3902 - 5 11 19 3 6 2 2 7 21 7 7 6 3 3 --- 7 4 5 5 5 143 13:47:00 - - --- 9 143 13:50:00 J0126+2559 - 565 419 485 221 425 --- --- 371 --- 180 --- --- 86 186 0 371 301 566 572 565 143 14:02:00 - - --- --- --- --- --- 10 143 14:05:00 J0126+2559 - 5 11 19 3 6 --- --- 7 --- 6 --- --- 3 3 11 7 4 5 5 5 143 14:17:00 - - --- --- --- --- --- 11 143 14:20:00 J0126+2559 - 5 11 19 3 6 --- --- 7 --- 6 --- --- 3 3 10 7 4 5 5 5 143 14:32:00 - - --- --- --- --- --- 12 143 14:35:00 J0126+2559 - 5 11 19 3 6 --- --- 7 --- 6 --- --- 3 3 10 7 4 5 5 5 143 14:47:00 - - --- --- --- --- --- 13 143 14:50:00 J0126+2559 - 5 11 19 3 6 --- --- 7 --- 6 --- --- 3 3 10 7 4 5 5 5 143 15:00:00 - - --- --- --- --- --- TIME RANGE OF RECORDINGS and TOTAL BYTES: Obs. start time. Obs. end time. Total Station Day Time Day Time GBytes (UT) (UT) JODRELL2 143 12:00:00 143 15:00:00 541.0 WSTRBORK 143 12:00:00 143 15:00:00 541.0 EFLSBERG 143 12:00:00 143 15:00:00 541.0 MEDICINA 143 12:00:00 143 15:00:00 541.0 ONSALA85 143 12:00:00 143 15:00:00 541.0 TIANMA65 143 12:00:00 143 13:47:00 316.9 URUMQI 143 12:00:00 143 13:47:00 315.4 TORUN 143 12:00:00 143 15:00:00 538.5 HART 143 12:00:00 143 13:47:00 316.9 SVETLOE 143 12:00:00 143 15:00:00 538.5 ZELENCHK 143 12:00:00 143 13:47:00 315.4 BADARY 143 12:00:00 143 13:47:00 315.4 IRBENE 143 12:00:00 143 15:00:00 541.0 SARDINIA 143 12:00:00 143 15:00:00 541.0 ARECIBO 143 13:50:00 143 15:00:00 222.7 TR_VDIF 143 12:00:00 143 15:00:00 541.0 CAMBG32M 143 12:00:00 143 15:00:00 541.0 DARNHALL 143 12:00:00 143 15:00:00 541.0 DEFFORD 143 12:00:00 143 15:00:00 541.0 PICKMERE 143 12:00:00 143 15:00:00 541.0 POSITIONS OF SOURCES USED IN RECORDING SCANS Catalog positions marked with *. Precession of date coordinates is based on stop time of first scan. Names used in schedule marked with *. Observation date used in B1950/J2000 coordinate conversion (PRECDATE): 1979.900 No adjustments are made for rates (DRA, DDEC). Source Source position (RA/Dec) Error (B1950) (J2000) (Date) (mas) 0123+257 01 23 57.254018 * 01 26 42.792637 01 27 44.985331 0.02 * J0126+2559 25 43 27.95559 * 25 59 01.30013 26 04 45.20203 0.04 J0126+25 /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc GSFC 2016a X/S astro solution, 1574 observations. 4C39.25 09 23 55.319216 * 09 27 03.013937 09 28 13.816517 0.31 * J0927+3902 39 15 23.56644 * 39 02 20.85185 38 57 27.48533 0.16 0923+392 /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc J0927+39 GSFC 2016a X/S astro solution, 250526 observations. SOURCE SCAN SUMMARY FOR SOURCES LISTED ABOVE Scan hours are for recording scans only. Baseline hours are only counted for scans above horizon at both ends. Source Setup file Frequency sets Observing hours (duplicates not shown) Scan Baseline J0126+2559 sess219.L512 1 2 3 4 5 8 10 13 14 15 16 + 0.967 90.896 J0927+3902 sess219.L512 1 2 3 4 5 6 7 8 9 10 13 14 + 1.367 233.700 EFFECT OF SOLAR CORONA The solar corona can cause unstable phases for sources too close to the Sun. SCHED provides warnings at individual scans for distances less than 10 degrees. The distance from the Sun to each source in this schedule is: Source Sun distance (deg) J0126+2559 35.3 J0927+3902 71.2 Barry Clark estimates from predictions by Ketan Desai of IPM scattering sizes that the Sun will cause amplitude reductions on the longest VLBA baselines at a solar distance of 60deg F^(-0.6) where F is in GHz. For common VLBI bands, this is: 327 MHz 117. deg 610 MHz 81. deg 1.6 GHz 45. deg 2.3 GHz 36. deg 5.0 GHz 23. deg 8.4 GHz 17. deg 15.0 GHz 12. deg 22.0 GHz 9. deg 43.0 GHz 6. deg SOURCE SEPARATIONS Source separations in degrees for pairs closer than 30.00 degrees. CATALOGS, FILES, and CODE VERSIONS Catalogs: Station: ../sta.sess219.115_RDBE.dat Version: 2018Sep07-20:14:11 Location: ../loc.sess219.115.dat Version: 2016Dec19-16:00:00 Frequency: /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat Version: 2018Sep07-20:14:11 Source: /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc Version: Not given Source2: NONE Version: --- Other external files: Ephemeris: NONE PEAKFILE: /home/guest/rmc/SCHED/sched11.5/catalogs/peak.cmd MSGFILE: /home/guest/rmc/SCHED/sched11.5/catalogs/messages.txt Code versions: Release version: 11.50 Development version 11.5. Started Apr. 2 Version of VEX standard: 1.50 Version of VEX code: 0.87 Version of plot code: 1.06 Version of ephemeris code: 0.00 Version of PGPLOT: v5.3.1 This schedule produced on: Thu May 23 07:29:31 2019