  COVER INFORMATION 

 Station:    HART      (Code Hh ) 
 Experiment: Network Monitoring Experiment
 Exp. Code:  N24C2   


Schedule Version:       1.00
Processed by SCHED version:  11.60  Release 11.6; Feburary 2020

PI:       Benito Marcote

Address:  JIVE
          Oude Hoogeveensedijk 4
          7991PD Dwingeloo
          The Netherlands

Phone:    +31 521 596 508
EMAIL:    marcote@jive.eu
Fax:
Phone during observation: +31 521 596 508

Observing mode:

Notes:    6cm NME and ftp fringe test for Session 2 2024
          4096 Mbps, L+R, 2-bit sampling, 32 MHz filters
          Please send the disk pack by express to JIVE
          Please DO NOT use the phase cal signal.


COVER LETTER:


This is the schedule for the 6cm NME and ftp fringe-test on 31st May 2024
involving the following (10) antennas:
Jb2 Wb1 Ef Mc On85 Tr Ys Hh Ir Sr

The NME uses a standard setup with 4096 Mbps.

The schedule consists of long integrations on the calibrator J0854+2006.
We shall use J0905+2052 in one scan for phase referencing check purposes.

The following ftp-fringe tests are scheduled throughout the experiment (UT times):
12:10:00 (scan 2, 2 s, J0854+2006)
12:40:00 (scan 4, 2 s, J0854+2006)
13:10:00 (scan 6, 2 s, J0854+2006)
13:40:00 (scan 8, 2 s, J0854+2006)
14:10:00 (scan 10, 2 s, J0854+2006)
14:40:00 (scan 12, 2 s, J0854+2006)
14:58:00 (scan 16, 2 s, J0854+2006)


Good fringes to everyone!

Benito Marcote
Mattermost: coms.evlbi.org

Schedule for HART      (Code Hh )                                   Page   2
               Network Monitoring Experiment
  UP:  D => Below limits;  H => Below horizon mask;  W => still slewing at end;  blank => Up.
  Early: Seconds between end of slew and start.   Dwell: On source seconds. 
  Disk: GBytes recorded to this point.
  TPStart:  Recording start time.  Frequencies are LO sum (band edge).
  SYNC: Time correlator is expected to sync up.
----------------------------------------------------------------------------------------
Start UT  Source               Start / Stop                 Early    Disk   TPStart
Stop UT                  LST      EL    AZ   HA  UP   ParA  Dwell   GBytes    SYNC
----------------------------------------------------------------------------------------

 --- Fri  31 May 2024   Day 152 ---

 Next scan frequencies:  4632.00  4632.00  4632.00  4632.00  4696.00  4696.00  4696.00  4696.00
                         4760.00  4760.00  4760.00  4760.00  4824.00  4824.00  4824.00  4824.00
                         4888.00  4888.00  4888.00  4888.00  4952.00  4952.00  4952.00  4952.00
                         5016.00  5016.00  5016.00  5016.00  5080.00  5080.00  5080.00  5080.00
 Next BBC frequencies:     32.00    32.00    32.00    32.00    96.00    96.00    96.00    96.00
                          160.00   160.00   160.00   160.00   224.00   224.00   224.00   224.00
                          288.00   288.00   288.00   288.00   352.00   352.00   352.00   352.00
                          416.00   416.00   416.00   416.00   480.00   480.00   480.00   480.00
 Next scan bandwidths:     32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
                           32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
                           32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
                           32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00

12 00 00  J0854+2006   06 28 39  31.8  41.6 -2.5       0.0     0        0   12 00 00
12 05 00  =OJ287       06 33 40  32.5  40.5 -2.4       0.0   300      155   12 00 01

12 08 00  J0854+2006   06 36 41  33.0  39.8 -2.3       0.0   159      155   12 08 00
12 12 00  =OJ287       06 40 41  33.5  38.9 -2.3       0.0   240      278   12 08 01

12 17 00  J0854+2006   06 45 42  34.2  37.8 -2.2       0.0   279      278   12 17 00
12 27 00  =OJ287       06 55 44  35.6  35.4 -2.0       0.0   600      587   12 17 01

12 32 00  J0854+2006   07 00 45  36.2  34.2 -1.9       0.0   279      587   12 32 00
12 42 00  =OJ287       07 10 46  37.4  31.7 -1.8       0.0   600      897   12 32 01

12 47 00  J0854+2006   07 15 47  38.0  30.4 -1.7       0.0   279      897   12 47 00
12 57 00  =OJ287       07 25 49  39.1  27.7 -1.5       0.0   600     1206   12 47 01

13 02 00  J0854+2006   07 30 49  39.6  26.4 -1.4       0.0   279     1206   13 02 00
13 12 00  =OJ287       07 40 51  40.6  23.5 -1.3       0.0   600     1515   13 02 01

13 17 00  J0854+2006   07 45 52  41.0  22.1 -1.2       0.0   279     1515   13 17 00
13 27 00  =OJ287       07 55 54  41.8  19.1 -1.0       0.0   600     1824   13 17 01

13 32 00  J0854+2006   08 00 54  42.2  17.6 -0.9       0.0   279     1824   13 32 00
13 42 00  =OJ287       08 10 56  42.8  14.6 -0.8       0.0   600     2133   13 32 01

13 47 00  J0854+2006   08 15 57  43.1  13.0 -0.7       0.0   279     2133   13 47 00
13 57 00  =OJ287       08 25 58  43.5   9.8 -0.5       0.0   600     2442   13 47 01

14 02 00  J0854+2006   08 30 59  43.7   8.2 -0.4       0.0   279     2442   14 02 00
14 12 00  =OJ287       08 41 01  43.9   5.0 -0.3       0.0   600     2752   14 02 01

14 17 00  J0854+2006   08 46 02  44.0   3.3 -0.2       0.0   279     2752   14 17 00
14 27 00  =OJ287       08 56 03  44.1   0.0 -0.0       0.0   600     3061   14 17 01
Schedule for HART      (Code Hh )                                   Page   3
               Network Monitoring Experiment
  UP:  D => Below limits;  H => Below horizon mask;  W => still slewing at end;  blank => Up.
  Early: Seconds between end of slew and start.   Dwell: On source seconds. 
  Disk: GBytes recorded to this point.
  TPStart:  Recording start time.  Frequencies are LO sum (band edge).
  SYNC: Time correlator is expected to sync up.
----------------------------------------------------------------------------------------
Start UT  Source               Start / Stop                 Early    Disk   TPStart
Stop UT                  LST      EL    AZ   HA  UP   ParA  Dwell   GBytes    SYNC
----------------------------------------------------------------------------------------

 --- Fri  31 May 2024   Day 152 ---

14 32 00  J0854+2006   09 01 04  44.1 358.4  0.1       0.0   279     3061   14 32 00
14 42 00  =OJ287       09 11 06  44.0 355.1  0.2       0.0   600     3370   14 32 01

14 46 00  J0854+2006   09 15 07  43.9 353.8  0.3       0.0   219     3370   14 46 00
14 48 00  =OJ287       09 17 07  43.8 353.2  0.3       0.0   120     3432   14 46 01

14 48 00  J0905+2052   09 17 07  43.3 356.6  0.2       0.0   -32     3432   No stop 
14 51 00  ---          09 20 07  43.2 355.7  0.2       0.0   148     3524   14 48 01

14 51 30  J0854+2006   09 20 37  43.7 352.1  0.4       0.0    -2     3524   14 51 30
14 53 00  =OJ287       09 22 08  43.7 351.6  0.4       0.0    88     3571   14 51 31

14 56 00  J0854+2006   09 25 08  43.6 350.6  0.5       0.0   159     3571   14 56 00
15 00 00  =OJ287       09 29 09  43.4 349.3  0.5       0.0   240     3695   14 56 01


SETUP FILE INFORMATION:
   NOTE: If DOPPLER, FREQ, or BW were used, see the individual scans for the final BBC settings.


 ======== Setup file: sess224.C4096
   Matching groups in /Users/hawky/.pysched/catalogs/freq_RDBE.dat:
     hh6cm_g         Generated from sess119C2Gglob.setini, sess119C5nme.setini, sess119CGline.setini*
    ****** Only  748.00 of 1024.00 MHz total bandwidth is within the IFs
           in the setup file before any FREQ or DOPPLER shifts.

   Setup group:    4         Station: HART              Total bit rate:  4096
   Format: VDIF              Bits per sample: 2         Sample rate: 64.000
   Number of channels: 32    DBE type: DBBC_DDC         Speedup factor:   1.00

   Disk used to record data.

   1st LO=   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00
             4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00
             4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00
             4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00   4600.00
   Net SB=         L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
   IF SB =         U         U         U         U         U         U         U         U
                   U         U         U         U         U         U         U         U
                   U         U         U         U         U         U         U         U
                   U         U         U         U         U         U         U         U
   Pol.  =      RCP       LCP       RCP       LCP       RCP       LCP       RCP       LCP 
                RCP       LCP       RCP       LCP       RCP       LCP       RCP       LCP 
                RCP       LCP       RCP       LCP       RCP       LCP       RCP       LCP 
                RCP       LCP       RCP       LCP       RCP       LCP       RCP       LCP 
   BBC   =         1         9         1         9         2        10         2        10
                   3        11         3        11         4        12         4        12
                   5        13         5        13         6        14         6        14
                   7        15         7        15         8        16         8        16
   BBC SB=         L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
                   L         L         U         U         L         L         U         U
   IF    =        A1        C1        A1        C1        A1        C1        A1        C1
                  A1        C1        A1        C1        A1        C1        A1        C1
                  B2        C1        B2        C1        B2        C1        B2        C1
                  B2        C1        B2        C1        B2        C1        B2        C1

  The following frequency sets based on these setups were used.

   Frequency Set:   8  Setup file default.  Used with PCAL = off
   LO sum=   4632.00  4632.00  4632.00  4632.00  4696.00  4696.00  4696.00  4696.00
             4760.00  4760.00  4760.00  4760.00  4824.00  4824.00  4824.00  4824.00
             4888.00  4888.00  4888.00  4888.00  4952.00  4952.00  4952.00  4952.00
             5016.00  5016.00  5016.00  5016.00  5080.00  5080.00  5080.00  5080.00
   BBC fr=     32.00    32.00    32.00    32.00    96.00    96.00    96.00    96.00
              160.00   160.00   160.00   160.00   224.00   224.00   224.00   224.00
              288.00   288.00   288.00   288.00   352.00   352.00   352.00   352.00
              416.00   416.00   416.00   416.00   480.00   480.00   480.00   480.00
   Bandwd=     32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
               32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
               32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
               32.00    32.00    32.00    32.00    32.00    32.00    32.00    32.00
    Matching frequency sets:   8

   Track assignments are: 
    track1=   1,  2,  3,  4,  5,  6,  7,  8,  9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32
    barrel=roll_off 

 POSITIONS OF SOURCES USED IN RECORDING SCANS

   Source                         Source position (RA/Dec)                        Error
                        (B1950)             (J2000)             (Date)            (mas)

 * J0905+2052        09 02 22.789418   * 09 05 14.337300     09 06 37.205736       0.00
                     21 04 13.50391    * 20 52 13.30700      20 46 29.52425        0.00
                     From catalog imbedded in main SCHED input file.

   OJ287             08 51 57.250615   * 08 54 48.874927     08 56 11.720355       0.00
 * J0854+2006        20 17 58.41740    * 20 06 30.64085      20 01 02.38768        0.00
   0851+202          /Users/hawky/.pysched/catalogs/sources.gsfc
   J0854+20          GSFC 2016a X/S astro solution, 270807 observations.



SOURCE SCAN SUMMARY FOR SOURCES LISTED ABOVE

     Scan hours are for recording scans only. 
     Baseline hours are only counted for scans above horizon at both ends.
  Source       Setup file             Frequency sets                  Observing hours
                                   (duplicates not shown)              Scan  Baseline
  J0905+2052 sess224.C4096         1 2 3 4 5 6 8 10                  0.050     1.878
  J0854+2006 sess224.C4096         1 2 3 4 5 6 8 10                  1.942    87.312


EFFECT OF SOLAR CORONA

  The solar corona can cause unstable phases for sources too close to the Sun.
  SCHED provides warnings at individual scans for distances less than 10 degrees.
  The distance from the Sun to each source in this schedule is:
    Source         Sun distance (deg) 
   J0905+2052          62.5
   J0854+2006          60.3

  Barry Clark estimates from predictions by Ketan Desai of IPM scattering sizes 
  that the Sun will cause amplitude reductions on the  longest VLBA baselines 
  at a solar distance of 60deg F^(-0.6) where F is in GHz. 
  For common VLBI bands, this is: 
       327 MHz        117. deg 
       610 MHz         81. deg 
       1.6 GHz         45. deg 
       2.3 GHz         36. deg 
       5.0 GHz         23. deg 
       8.4 GHz         17. deg 
      15.0 GHz         12. deg 
      22.0 GHz          9. deg 
      43.0 GHz          6. deg 

