!  Apriori edit data for EC063D
!  The format is appropriate for UVFLG in AIPS.
!  There is one flag per station per scan covering time from start of tape 
!    motion to antenna arrival on source, if that is a positive interval.
!  These flags are not needed when there are monitor data flags (eg VLBA).
! 
opcode = 'FLAG'
dtimrang = 1  timeoff = 0 
ant_name='Ef' timerang= 66,21,28,40,  66,21,28,42  reason='Slewing expected.' /
ant_name='Ef' timerang= 66,22,23,22,  66,22,23,24  reason='Slewing expected.' /





ant_name='T6' timerang= 66,21,12,29,  66,21,12,59  reason='Source set.' /

ant_name='Ur' timerang= 66,23,47,44,  66,23,57,44  reason='Source set.' /

ant_name='Ys' timerang= 66,22,27,54,  66,22,29,31  reason='Slewing expected.' /
ant_name='Ys' timerang= 66,22,27,55,  66,22,28,55  reason='Source rise.' /


ant_name='Hh' timerang= 66,23,31,00,  66,23,34,00  reason='Source set.' /


ant_name='Jb' timerang= 66,23,23,59,  66,23,24,01  reason='Slewing expected.' /