COVER INFORMATION Station: JODRELL2 (Code Jb ) Experiment: FTP Fringe Test Exp. Code: F23M1 Schedule Version: 1.00 Processed by SCHED version: 11.60 Release 11.6; April 2020 PI: Gabor Orosz Address: JIVE Oude Hoogeveensedijk 4 Dwingeloo Netherlands Phone: +31 521 596 530 EMAIL: orosz@jive.eu Fax: Phone during observation: +31 521 596 530 Observing mode: vlbi Notes: M-band (5cm) ftp fringe test for Session 3, 2023. 1Gbps/4IF/32MHz/dual/2bit, evn5cm-1Gbps-32MHz.set COVER LETTER: This is the schedule for the 5cm FTP-FT on October 23, 2023 involving the following 10 antennas: Jb2, Wb1, Ef, Mc, Nt, On85, T6, Tr, Hh, Ib. The FTP-FT uses a standard 1 Gbps setup (8BBC/32MHz/dual). The FTP-FT lasts for 1 hour (23/10, 10:30-11:30 UT) with long scans on calibrator: J1613+3412 -- https://obs.vlba.nrao.edu/cst/calibsource/12148 with ftp grabs every other scan at the following times (in UT): 10:35:00 (scan 2, 2 sec, J1613+3412) 10:50:00 (scan 4, 2 sec, J1613+3412) 11:10:00 (scan 6, 2 sec, J1613+3412) 11:29:00 (scan 8, 2 sec, J1613+3412) A longer NME will follow this short initial fringe test in two days. -- Gabor Orosz Mattermost: coms.evlbi.org Schedule for JODRELL2 (Code Jb ) Page 2 FTP Fringe Test UP: D => Below limits; H => Below horizon mask; W => still slewing at end; blank => Up. Early: Seconds between end of slew and start. Dwell: On source seconds. Disk: GBytes recorded to this point. TPStart: Recording start time. Frequencies are LO sum (band edge). SYNC: Time correlator is expected to sync up. ---------------------------------------------------------------------------------------- Start UT Source Start / Stop Early Disk TPStart Stop UT LST EL AZ HA UP ParA Dwell GBytes SYNC ---------------------------------------------------------------------------------------- --- Mon 23 Oct 2023 Day 296 --- Next scan frequencies: 6603.49 6603.49 6635.49 6635.49 6667.49 6667.49 6699.49 6699.49 Next BBC frequencies: 834.51 834.51 802.51 802.51 770.51 770.51 738.51 738.51 Next scan bandwidths: 32.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 10 30 00 J1613+3412 12 27 08 46.1 92.2 -3.8 -46.3 0 0 10 30 00 10 32 00 =1611+343 12 29 09 46.4 92.6 -3.8 -46.3 120 15 10 30 01 10 33 00 J1613+3412 12 30 09 46.6 92.8 -3.7 -46.3 55 15 10 33 00 10 36 00 =1611+343 12 33 09 47.0 93.4 -3.7 -46.2 180 39 10 33 01 10 37 00 J1613+3412 12 34 09 47.2 93.6 -3.7 -46.2 55 39 10 37 00 10 41 00 =1611+343 12 38 10 47.8 94.5 -3.6 -46.1 240 70 10 37 01 10 43 00 J1613+3412 12 40 10 48.0 94.9 -3.6 -46.1 115 70 10 43 00 10 51 00 =1611+343 12 48 12 49.2 96.7 -3.4 -45.9 480 131 10 43 01 10 53 00 J1613+3412 12 50 12 49.5 97.1 -3.4 -45.9 115 131 10 53 00 11 01 00 =1611+343 12 58 13 50.7 98.9 -3.3 -45.6 480 193 10 53 01 11 03 00 J1613+3412 13 00 14 51.0 99.4 -3.2 -45.5 115 193 11 03 00 11 11 00 =1611+343 13 08 15 52.2 101.3 -3.1 -45.2 480 255 11 03 01 11 13 00 J1613+3412 13 10 15 52.5 101.7 -3.1 -45.1 115 255 11 13 00 11 20 00 =1611+343 13 17 17 53.5 103.4 -3.0 -44.7 420 309 11 13 01 11 22 00 J1613+3412 13 19 17 53.8 103.9 -2.9 -44.6 115 309 11 22 00 11 30 00 =1611+343 13 27 18 55.0 106.0 -2.8 -44.1 480 371 11 22 01 SETUP FILE INFORMATION: NOTE: If DOPPLER, FREQ, or BW were used, see the individual scans for the final BBC settings. ======== Setup file: sess323.M1024_32u --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 3 Station: JODRELL2 Total bit rate: 1024 Format: VDIF Bits per sample: 2 Sample rate: 64.000 Number of channels: 8 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 7438.00 7438.00 7438.00 7438.00 7438.00 7438.00 7438.00 7438.00 Net SB= U U U U U U U U IF SB = L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 2 10 3 11 4 12 BBC SB= L L L L L L L L IF = A2 B2 A2 B2 A2 B2 A2 B2 The following frequency sets based on these setups were used. Frequency Set: 1 Setup file default. Used with PCAL = off LO sum= 6603.49 6603.49 6635.49 6635.49 6667.49 6667.49 6699.49 6699.49 BBC fr= 834.51 834.51 802.51 802.51 770.51 770.51 738.51 738.51 Bandwd= 32.00 32.00 32.00 32.00 32.00 32.00 32.00 32.00 Matching frequency sets: 1 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8 barrel=roll_off POSITIONS OF SOURCES USED IN RECORDING SCANS Source Source position (RA/Dec) Error (B1950) (J2000) (Date) (mas) 1611+343 16 11 47.914252 * 16 13 41.064243 16 14 33.403986 0.13 * J1613+3412 34 20 19.83388 * 34 12 47.90890 34 09 20.37144 0.16 J1613+34 /home/guest/rmc/SCHED/sched11.6/catalogs/sources.gsfc GSFC 2016a X/S astro solution, 162031 observations. SOURCE SCAN SUMMARY FOR SOURCES LISTED ABOVE Scan hours are for recording scans only. Baseline hours are only counted for scans above horizon at both ends. Source Setup file Frequency sets Observing hours (duplicates not shown) Scan Baseline J1613+3412 sess323.M1024_32u 1 2 3 4 5 6 7 8 9 0.800 44.000 EFFECT OF SOLAR CORONA The solar corona can cause unstable phases for sources too close to the Sun. SCHED provides warnings at individual scans for distances less than 10 degrees. The distance from the Sun to each source in this schedule is: Source Sun distance (deg) J1613+3412 56.9 Barry Clark estimates from predictions by Ketan Desai of IPM scattering sizes that the Sun will cause amplitude reductions on the longest VLBA baselines at a solar distance of 60deg F^(-0.6) where F is in GHz. For common VLBI bands, this is: 327 MHz 117. deg 610 MHz 81. deg 1.6 GHz 45. deg 2.3 GHz 36. deg 5.0 GHz 23. deg 8.4 GHz 17. deg 15.0 GHz 12. deg 22.0 GHz 9. deg 43.0 GHz 6. deg